Ion beams against cancer

TU Wien and MedAustron have achieved an important milestone on the way toward even more precise cancer treatment. A new approach combines carbon and helium ions with the aim of irradiating tumors while simultaneously monitoring the patient anatomy in the future.

two people in the command center in front of multiple screens

© TU Wien

Matthias Kausel (MedAustron/TU Wien) and Elisabeth Renner (TU Wien)

In ion beam therapy, atomic nuclei are accelerated to high energies in a particle accelerator, such as a synchrotron, and precisely directed at a tumor. There, they damage cancer cells and destroy tumor tissue. This technique is now used at several specialized medical facilities around the world, including MedAustron in Wiener Neustadt, Austria.

A new and promising approach currently under investigation involves so-called “mixed beams”, which consist of two different ion species: Carbon nuclei destroy the tumor cells, while helium nuclei simultaneously provide imaging information about the patient anatomy during irradiation. To make this possible, however, the precise ratio of carbon to helium in the beam must be known. But how can an ion beam be measured while it is being used for treatment? TU Wien and MedAustron have now found an elegant solution – an important step on the path toward cancer treatment using mixed ion beams.

Irradiating as little as possible

Despite the high precision of ion beam therapy, uncertainties remain. Organ motion, for example, can shift the depth at which the ions stop and deposit most of their energy – in other words, the range of the beam – by a few millimeters. To ensure that the entire tumor is treated despite these uncertainties, a small safety margin around the tumor is irradiated as well. The smaller this margin can be made, the more precise the therapy becomes and the better sensitive organs near the tumor can be spared.

To minimize side effects, it would therefore be ideal to monitor the relevant patient anatomy as precisely as possible during treatment. This is where the concept of mixed beams comes in: Carbon and helium ions are combined in a single beam. All electrons are removed, leaving carbon nuclei with exactly three times the electric charge of helium nuclei and almost exactly three times their mass.

“Because their charge-to-mass ratios are almost identical, the two ion species also follow almost exactly the same trajectory in the particle accelerator, allowing us to accelerate them simultaneously to high energies and direct them toward the patient,” explains Elisabeth Renner.

In tissue, however, a crucial difference emerges: At a similar energy per unit mass, helium ions have approximately three times the range of carbon ions. A mixed beam can therefore be sent through the body in such a way that the carbon ions are used to destroy the tumor tissue, while the helium ions pass through the patient.

The emerging helium ions can then be measured. By measuring their position and residual energy, information about the tissue they have passed through can be reconstructed. This makes it possible to image the patient anatomy and detect changes that could alter the range of the carbon ions. In the future, this could make it possible to reduce safety margins and spare even more healthy tissue, particularly in the case of tumors located very close to sensitive organs.

“For this method to work, however, we need to know and control how large the carbon and helium fractions in the beam are,” says Elisabeth Renner. And that is a major challenge: Either the beam is measured, or it is used for irradiation. Doing both at the same time is difficult.

Graphic depiction of ions flying through a stylized head

© TU Wien

A mixed beam of carbon- and helium ions

How to measure a beam without stopping it

The research team at TU Wien and MedAustron has now found an elegant solution. Strictly speaking, a carbon nucleus does not have exactly three times the mass of a helium nucleus: it is about 0.065% lighter than three helium nuclei combined. This tiny difference means that carbon and helium are forced onto slightly different trajectories inside the particle accelerator.

“In the accelerator, we continuously monitor whether the center of the particle beam remains on its intended trajectory,” explains Elisabeth Renner. “If it deviates, the accelerator’s radio frequency is adjusted ever so slightly. Because helium and carbon nuclei behave slightly differently due to their tiny mass difference, the required frequency correction depends on the mixing ratio.”

By precisely monitoring the frequency needed to stabilize the beam, the carbon-to-helium ratio can therefore be determined.

This was calculated at TU Wien and tested in collaboration with MedAustron – and the results show good agreement. “We were able to demonstrate that this method allows us to determine the helium and carbon fractions in the beam without affecting or interrupting the beam itself. This means that during experiments, and possibly also during treatments in the future, we can check whether the helium fraction in the beam corresponds to the desired value. In a future clinical system, the beam could then be cleared for irradiation only if the mixing ratio is within the required range.”

The results have now been published and are already attracting international attention: On October 8 and 9, 2026, researchers from a range of international particle accelerator facilities came to TU Wien for the “1st Workshop on Mixed Ion Beam Delivery” to discuss current developments and challenges in the delivery and use of mixed ion beams.

Original publication


E. Renner et al., Noninvasive ion fraction quantification of dual-species beams in synchrotrons, Phys. Rev. Accel. Beams 29, 093802, DOI: https://doi.org/10.1103/5bxb-lp5d., opens an external URL in a new window

Contact

Dr. Elisabeth Renner
Institute for Atomic and Subatomic Physics
TU Wien
elisabeth.renner@tuwien.ac.at